High-quality PVC 3 & 4 core flat submersible pump cables with finely stranded flexible copper conductors for excellent conductivity and durability. Designed for continuous use in deep wells and water pumping systems with superior resistance to moisture, abrasion, grease, and oil. Suitable for heavy-duty power supply applications where flexibility and robustness are essential. Conforms to international standards like IEC 60227, BS 6500, and IS 694.
For continuous use in deep wells to supply power to submersible motors for depths up to 500 metres.
| Conductor | PVC Insulation | PVC Sheath / Overall Dimensions | Conductor Resistance at 20°C (Max) Ω/km | Current Rating at 40°C (Amps) | ||||
|---|---|---|---|---|---|---|---|---|
| Nominal Size (sq. mm) | Nos. & Dia. of Wire (Nos./mm) | Nominal Thickness (mm) | Nominal Core Dia. (mm) | Nominal Thickness (mm) | Height (mm) | Width (mm) | ||
| 1.50 | 22/0.30 | 0.80 | 3.25 | 1.15 | 6.20 | 12.80 | 12.10 | 14 |
| 2.50 | 36/0.30 | 0.90 | 3.80 | 1.15 | 6.40 | 14.60 | 7.41 | 18 |
| 4.00 | 56/0.30 | 1.00 | 4.50 | 1.15 | 7.40 | 16.60 | 4.95 | 26 |
| 6.00 | 84/0.30 | 1.00 | 5.25 | 1.15 | 7.90 | 18.60 | 3.30 | 31 |
| 10.00 | 140/0.30 | 1.00 | 6.50 | 1.40 | 9.90 | 23.70 | 1.91 | 42 |
| 16.00 | 224/0.30 | 1.00 | 8.00 | 1.40 | 11.80 | 28.00 | 1.21 | 57 |
| 25.00 | 350/0.30 | 1.20 | 10.10 | 2.00 | 14.70 | 35.50 | 0.780 | 72 |
| 35.00 | 490/0.30 | 1.20 | 11.30 | 2.00 | 16.80 | 39.50 | 0.554 | 90 |
| 50.00 | 703/0.30 | 1.40 | 13.50 | 2.20 | 18.00 | 45.50 | 0.386 | 115 |
| 70.00 | 988/0.30 | 1.40 | 15.30 | 2.20 | 20.00 | 51.00 | 0.272 | 143 |
| 95.00 | 1349/0.30 | 1.60 | 18.00 | 2.40 | 23.50 | 60.00 | 0.206 | 165 |
| 120.00 | 608/0.50 | 1.90 | 19.80 | 2.80 | 25.00 | 65.00 | 0.161 | 188 |
| 150.00 | 760/0.50 | 2.20 | 22.70 | 4.00 | 30.70 | 76.10 | 0.129 | 216 |
| Conductor | PVC Insulation | PVC Sheath / Overall Dimensions | Conductor Resistance at 20°C (Max) Ω/km | Current Rating at 40°C (Amps) | ||||
|---|---|---|---|---|---|---|---|---|
| Nominal Size (sq. mm) | Nos. & Dia. of Wire (Nos./mm) | Nominal Thickness (mm) | Nominal Core Dia. (mm) | Nominal Thickness (mm) | Height (mm) | Width (mm) | ||
| 1.50 | 22/0.30 | 0.80 | 3.25 | 1.30 | 6.20 | 15.80 | 12.10 | 14 |
| 2.50 | 36/0.30 | 0.90 | 3.80 | 1.30 | 6.40 | 18.00 | 7.41 | 18 |
| 4.00 | 56/0.30 | 1.00 | 4.50 | 1.45 | 7.40 | 21.00 | 4.95 | 26 |
| 6.00 | 84/0.30 | 1.00 | 5.25 | 1.50 | 7.90 | 24.50 | 3.30 | 31 |
| 10.00 | 140/0.30 | 1.00 | 6.50 | 1.80 | 9.90 | 29.70 | 1.91 | 42 |
| 16.00 | 224/0.30 | 1.00 | 8.00 | 1.95 | 11.80 | 36.00 | 1.21 | 57 |
| 25.00 | 350/0.30 | 1.20 | 10.10 | 2.00 | 14.70 | 45.10 | 0.780 | 72 |
| 35.00 | 490/0.30 | 1.20 | 11.30 | 2.00 | 16.80 | 50.10 | 0.554 | 90 |
| 50.00 | 703/0.30 | 1.40 | 13.50 | 2.20 | 18.20 | 58.20 | 0.386 | 115 |
| 70.00 | 988/0.30 | 1.40 | 15.30 | 2.20 | 20.00 | 66.50 | 0.272 | 143 |
| 95.00 | 1349/0.30 | 1.60 | 18.00 | 2.40 | 23.50 | 77.30 | 0.206 | 165 |
| 120.00 | 608/0.50 | 1.80 | 19.80 | 3.50 | 27.80 | 87.00 | 0.161 | 188 |
| Cross Sectional Area (sq. mm) | Copper Construction (Nos./mm) | Insulation Thickness (mm) | Nominal Core Diameter (mm) | Sheath Thickness (mm) | Height (mm) | Width (mm) | Maximum Conductor Resistance at 20°C (Ω/km) | Current Rating at 40°C (Amps) |
|---|---|---|---|---|---|---|---|---|
| 0.50 | 16/0.200 | 0.60 | 2.20 | 0.90 | 4.30 | 8.90 | 39.00 | 4 |
| 0.75 | 24/0.200 | 0.60 | 2.45 | 0.90 | 4.50 | 9.50 | 26.00 | 7 |
| 1.00 | 32/0.200 | 0.60 | 2.70 | 0.90 | 4.70 | 10.20 | 19.50 | 12 |
| 1.50 | 30/0.250 | 0.60 | 2.80 | 0.90 | 4.90 | 10.50 | 13.30 | 14 |
| 2.50 | 50/0.250 | 0.70 | 3.50 | 1.00 | 5.70 | 12.60 | 7.98 | 18 |
| 4.00 | 56/0.300 | 0.80 | 4.00 | 1.00 | 6.60 | 14.80 | 4.95 | 26 |
| 6.00 | 84/0.300 | 0.80 | 5.10 | 1.10 | 7.40 | 17.70 | 3.30 | 31 |
| 10.00 | 140/0.300 | 1.00 | 6.30 | 1.40 | 9.30 | 22.30 | 1.91 | 42 |
| 16.00 | 224/0.300 | 1.00 | 7.50 | 1.40 | 10.80 | 26.30 | 1.21 | 57 |
| 25.00 | 350/0.300 | 1.20 | 10.10 | 2.00 | 14.70 | 35.50 | 0.780 | 72 |
| 35.00 | 490/0.300 | 1.20 | 11.30 | 2.00 | 16.80 | 39.50 | 0.554 | 90 |
| 50.00 | 703/0.300 | 1.40 | 13.50 | 2.20 | 18.00 | 45.50 | 0.386 | 115 |
| 70.00 | 988/0.300 | 1.40 | 15.30 | 2.20 | 20.00 | 51.00 | 0.272 | 143 |
| 95.00 | 1349/0.300 | 1.60 | 18.00 | 2.40 | 23.50 | 60.00 | 0.206 | 165 |
The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360.
In view of continuous improvements in design and process, specifications given here are subject to change without notice.
PVC 3 & 4 Core Flat Cables
Know More
PVC 3 & 4 Core Round Cables
Know More
PVC 3 & 4 Core Double Sheathed Round Cables
Know More
Rubber 3 & 4 Core Flat Cables EPDM
Know More
Rubber 3 & 4 Core Round Cables HO7RN-F
Know More
PVC 3 & 4 Core Flat Cables AWG
Know More
Rubber 3 & 4 Core Flat Cables-AWG EPDM
Know More
Explore Rolson’s range of dependable wires and cables for automotive, electrical, industrial, solar and specialised applications.